ÉMI-TÜV SÜD Kft.

Central Laboratory for Structural and Material Testing

Laboratory for Structural and Material Testing

Central Laboratory for Structural and Material Testing

With the help of laboratories accredited in Hungary and abroad, our team is dedicated to ensuring your personal safety and the interests of your enterprise through expertise, testing and certification.

 

 

 

 

 

 Testing area

 

 Conformity assessment for products

We perform testing in the following fields:

• concrete, reinforced concrete, pre-stressed

  concrete, steel, timber and other load-bearing

  structures

• buildings, structures

• parts of transporting and loading devices

• parts of agricultural and forestry equipments 

 

Testing of safety components for elevators:

• safety gears

• buffers

• drives

• mechanical safety locks

• end position switches

• position sensors 

 Main technical characteristics of the 
 laboratory

 

 Examples for typical tests

Surface area: 24 x 24 m

Lower structure: reinforced concrete (thickness: 1 m thick, weight: 3000 tons)

Loading capacity: 800 kN on the point of intersection of a 60 x 60 cm squarenet

Linear loading capacity: 1000 kN/m

Full height: 11,4 m

Full height under crane: 8,5 m

Static maximum load range (limit load): 50-10 000 kN

Dynamic loading capacity:

Type Max. loading capacity Max. stroke

AMSLER 600 kN 220 mm

AMSLER 60 kN 220 mm

MTS 250 kN 160 mm

Measuring tools:

Sensors for force, deformation and acceleration

Material handling possibilities:

hammer-headed cranes (2 pcs.)

bridge crane (1 pc.)

 

 • test of load-bearing capacity and fatigue of  
   bridgegirders and main girders of industrial 
   buildings

• fatigue tests of machinery components with  
  a cycle of over 1 million repeats

• static and dynamic tests of vehicle body
  resistance

• collision and vibration tests on units of large- 
  size vehicular devices (e.g. transformers of 
  rail locomotives)

• performing test of resistance on pre-cast

  reinforced concrete units of pedestrian
  bridge structures

• dynamic and static tests on electrical
  columns

• tests on suspension cables and special 
  electric cables

• the testing equipment of our laboratory is 
  also well-suited for performing site tests and

  measurements and thus stationary 
  structures, technological devices and  
  buildings can also easily be subjected to
  tests of resistance and condition.

• testing of elevators and their safety 
  devices; verification of the characteristics
  prescribed in the standard EN 81